With captive nails. Four integral clamps, two each end. Meets NEMA OS-2, UL Listed, classified for fire wall assemblies.
|
With captive nails. Four integral clamps, two each end. Meets NEMA OS-2, UL Listed, classified for fire wall assemblies.
|
With captive nails. Four integral clamps, two each end. Meets NEMA OS-2, UL Listed, classified for fire wall assemblies.
|
|
|
|
|
|
|
|
|
|
|
|
|
Lightweight design and durable plastic. Listed for masonry walls. Safe to install and will never rust or corrode. Includes nails for quick, easy installation. 22 cubic inch rigid wall. 3-7/8" x 2-3/8" x 3-3/4". UL Listed.
|
PVC handy box used for many wiring applications. Weather-resistant and nonconductive. Will accept metal handy box covers or nonmetallic covers. Includes hardware for quick, easy installation.
|
Old work wall case. Safe, non-conductive. Two Zip-Mount retainers. Four integral clamps, two each end; mounting ears. 14 cubic inch, 2-3/4" x 2-1/4" x 4-1/8". UL Listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
New work safe, non-conductive. With captive nails. Eight integral clamps, four each side. 32 cubic inches. Meets NEMA OS-2, UL Listed, classified for fire wall assemblies. 3" depth x 4" x 3-3/4".
|
Safe, non-conductive. With bracket for 3/8" to 5/8" wallboard. Steel and wood studs, 4 knockouts. 2-15/16" depth x 3-3/4" x 2-1/4".
|
New work applications, shallow PVC switch box. Integral brackets. 1-1/4" depth x 2-3/8" x 3-5/8". UL Listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
Thermoset-fiberglass, with angled mid-nails. Nails are installed as fastening devices. 2 hour wall and ceiling fire rating. Lightweight, non-corrosive, non-conductive, no ground required, will not melt or distort in high heat. Shatter resistant in cold temperatures. UL Listed.
|
Residential thermoplastic switch or receptacle box. With angled nails. 3-9/16" depth x 2-1/4" width x 3-3/4" height. 24 cubic inch volume. Fire rating classification of 2 hours in wall and ceiling. UL Listed.
|
Welded square steel box, no bracket, installed in ceilings or walls for lighting fixtures, switches or receptacles, used where multiple conductor runs are split into two or more directions to bring power to a number of electrical devices. TKO 1/2" and 3/4" eccentric knockouts (Per U.L. 514-A, suitable for use without a bonding jumper in circuits above or below 250 volts). Eight 1/2" and 4, TKO side knockouts, three 1/2" and 2 TKO bottom knockouts. Combination cover screw heads provide for faster mud ring/cover installation. UL 514-A Listed, File E195978. 21.0 cubic inch capacity. Acceptable for use in 2-hour rated walls.
|
|
|
|
|
|
|
|
|
|
|
|
|
Used where multiple conductor runs are split into two or more directions to bring power to a number of electrical devices. Drawn construction and raised grounding provision for exposed work or surface mount applications. Combination cover screw heads provide for faster mudring/cover installation. Twelve 1/2" conduit knockouts (sides). Four 1/2" conduit knockouts (bottom). No bracket. 4" square x 1-1/2" deep - 21.0 cubic inches. UL Listed, acceptable for use in 2-hour fire rated walls. UPC bar code.
|
Extends an existing box by 1-1/8". Used to correct problems from remodeling where the wall surface is extended. Fits between the wiring device and the wall surface. Extends the switch or outlet box to flush with the wall. Works with all standard wiring devices. 2-1/4" x 3-1/4". UL Listed.
|
Designed and listed for use with non-metallic sheathed cable. With mounting ears. Permissible for use with 90 degree C connectors. 8 cubic inch capacity. 1-1/4" depth x 2-3/8" x 3-5/8". UL Listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
Conduit wiring system. Installed in ceilings or walls for lighting fixtures, switches or receptacles. Used where multiple conductor runs are split into two or more directions to bring power to a number of electrical devices. Drawn construction and raised grounding provision for surface mount applications in ceilings or walls for lighting fixtures or receptacles. Eight 1/2"and four 3/4" conduit knockouts (sides). Two 1/2" and two 3/4" conduit knockouts (bottom). 4" square x 1-1/2" deep - 21.0 cubic inches. Acceptable for use in 2-hour rated fire walls. UL Listed. UPC bar code.
|
Plaster ears, old work swing style clips secure box in wall. Integral clamps. Two hour fire rated. Mounting clips. 3" depth. 14.0 cubic inch capacity. UL Listed.
|
Thermoset-fiberglass, with angled mid-nails. Nails are installed as fastening devices. 2 hour wall and ceiling fire rating. Lightweight, non-corrosive, non-conductive, no ground required, will not melt or distort in high heat. Shatter resistant in cold temperatures. UL Listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
For telecommunications and other low voltage wiring. Suitable for old work applications. 1.18" depth x 2.18" x 3.05".
|
Square 4" steel box for lighting fixtures, switches or receptacles where multiple conductor runs are split into two or more directions to bring power to a number of electrical devices. 1-1/2" deep. 21.0 cubic inch capacity. Welded, with six 1/2" and three TKO side knockouts, three 1/2" and two TKO bottom knockouts. Flush FH bracket type for side mount of stud and features hooks that drive into face of wood stud for hands-free installation. UL Listed.
|
Six 1/2" and 3 TKO conduit knockouts (sides). Three 1/2" and 2 TKO conduit knockouts (bottom). Combination cover screw heads provide for faster mudring/cover installation. FM bracket mounts flat on side of stud and provides a rigid, secure box installation. Square boxes are installed in ceiling or walls for lighting fixture or receptacles. 4" square x 1-1/2" deep - 21.0 cubic inches. UPC bar code. UL Listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
Non-metallic, non-conductive. Punch type knockout. Quickly connects. Square, fits commercial and residential requirements. For 600 volt use in ceilings, floors, and walls in commercial, industrial and residential buildings not more than three floors above grade. Colored in brilliant electric blue. 3" x 2-1/4" x 1-7/8". UL Listed.
|
Non-metallic, non-conductive. Punch type knockout. Quickly connects. Square, fits commercial and residential requirements. For 600 volt use in ceilings, floors, and walls in commercial, industrial and residential buildings not more than three floors above grade. Colored in brilliant electric blue. 3" x 2-1/4" x 1-7/8". UL Listed.
|
With mounting ears and swing bracket. 4 integral clamps, 2 each end. UL Listed, meets NEMA OS-2. Suitable for masonry walls, not UL Classified for Fire Resistance. PVC construction. 20 cubic inch capacity. 3-5/8" depth x 2-5/16" x 4-1/8".
|
|
|
|
|
|
|
|
|
|
|
|
|
Conduit wiring system. Eight 1/2" and four TKO conduit knockouts (sides). Two 1/2" and two TKO conduit knockouts (bottom). 4" square x 2-1/8" deep, 30.3 cubic inch capacity. Combination cover screw heads provide for faster mudring/cover installation. No bracket, installed in ceilings or walls for lighting fixtures and receptacles. Acceptable for use in 2-hour rated fire walls. With UPC bar code. UL Listed.
|
Backless bracket with nail on mounting and screw in bracket. Non-metallic. Non-conductive. 3.73" x 2.32".
|
Non-metallic. Non-conductive. Suitable for masonry walls. 4" x 4" x 1-1/2". 1/2" and 3/4" knockouts. UL Listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
PVC handy box used for many wiring applications. Weather-resistant and nonconductive. Will accept metal handy box covers or nonmetallic covers. 35 cubic inch rigid wall.
|
Gangable 3" x 2" switch box, offers the option of constructing a box to hold two or more devices. Beveled corners prevent the clamp screws from protruding into the back wall. With nonmetallic sheathed cable clamps. Acceptable for use in 2-hour fire rated walls. Four cable knockouts (end). Two 1/2" conduit knockouts (end). 1/2" conduit knockouts (bottom). With leveling bumps. No plaster ears, not suitable for old work. 2-1/4" deep - 10.5 cubic inches. UL Listed.
|
For installation of low-voltage devices in an existing wall. Thinner rectangular flange for faster, easier installation, less protrusion on the wall. Shallow bracket means less material, easier to work with. Can be installed vertically or horizontally. UL listed.
|
|