Home > ELECTRICAL > ROUGH ELECTRICAL > PANEL BOXES > DISCONNECT BOXES
Sort By:
1
GE Electrical TFN60RCP AC Disconnect Switches Eaton DPU222RP Type ACD Non-Fusible Pullout Disconnect Switch Siemens Energy WN2060U AC Disconnect Switches
Steel enclosure. 2 pole, 3 wire, 240 volt AC, rated 10 HP. For central air conditioner. Removable closing cap not included. Equipment ground. 14 - 3 AWG lug wire range. 4-3/4" x 7-1/2" x 2". UL1429 enclosure pullout switch, UL Listed. Single phase, 2 pole, 2 wire, 240 volt AC, galvanized steel enclosure with molded case switch. Rated 3 HP at 120 volt, 10 HP at 240 volt. For bottom entry and exit only. Heavy duty, high strength enclosure with welded and riveted construction. Swing-up cover remains in place when in open position, and includes provision for padlocking. 10,000 AIR. When pullout is in off position, protective shield can be removed for access to fuses. No.GB4 ground bar and No.96-3258-4 pullout head replacement sold separately. #14-3 AWG wire range. 5-3/8" x 8-3/4" x 3-1/8". UL Listed file No.E5239. Single phase, 2 pole, 2 wire, 240 volt, rated 10 HP, steel enclosure. All lugs positioned for bottom entry and exit wiring. Easy mounting for quick installation. Pullout head can be replaced in off position. 10,000 AIR. 12 - 3 AWG al, 14 - 3 kcmil cu lug wire range. 5-5/32" x 7-5/16" x 2-7/32". UL Listed.
Cutler-Hammer DPF221RP AC Disconnect Switches Cutler-Hammer DPF222RP AC Disconnect Switches Cutler-Hammer AC222URNMP-A2 AC Disconnect Switches
Air conditioning disconnect, pullout, fused, 2-pole, 120/240 volt AC. Wire size range of  #14-3 Cu or Al at 60 or 70 degrees C. Metallic color galvanized steel enclosure, 9" x 5.5" x 3". NEMA 3R, rainproof. UL Listed, CSA Approved. Air conditioning disconnect, pullout, fused, 2-pole, 120/240 volt AC. Wire size range of  #14-3 Cu or Al at 60 or 70 degrees C. Metallic color galvanized steel enclosure, 9" x 5.5" x 3". NEMA 3R, rainproof. UL Listed, CSA Approved. Single phase, 2 pole, 2 wire, 240 volt AC. Rated 3 HP at 120 volt, 10 HP at 240 volt. For top and bottom entry and exit, with provision for type H conduit hub. Heavy duty, high strength, rugged polymer enclosure with UV resistant features. Swing-up cover remains in place when in open position, protective shield can be removed for access to fuses. No.GB4 ground bar and No.360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5" x 8-5/8" x 3-1/2". UL Listed file No. E5239.
Square D QO200TRCP Molded Non-Fusible Disconnect Switch GE Electrical TPN60R1 AC Disconnect Switches GE Electrical TF60RCP AC Disconnect Switches
For use with 75 degree Celsius wire. 2 pole, 2 wire, 240 volt AC, rated 10 HP, steel enclosure with molded case. With reliable, quick-make, quick-break operating mechanism. Suitable for use on systems with up to 10,000 RMS symmetrical amp available fault current at 240 volt AC maximum when protected by a fuse or circuit breaker rated 60 amp or less. Does not contain overcurrent protection. Ground bar bonded to back. 4-5/8" x 6-1/2" x 3-7/8". UL Listed. Suitable for use as service entrance equipment. Removable closing cap not included. Equipment ground. 14 - 3 AWG lug wire range. Designed to comply with code requirements for disconnecting central air conditioners and heat pumps. Open sides and top for quick installation. Impact and corrosion resistant GE Noryl thermoplastic resin. 2 pole, 3 wire, 120/240 volt AC, rated 10 HP. 5-3/4" x 8" x 3-1/8". UL1429 enclosed pullout switch, UL Listed. Steel enclosure. 2 pole, 3 wire, 120/240 volt AC, rated 10 HP. Uses cartridge fuses. For central air conditioner. Designed to comply with code requirements for disconnecting means within sight of central air conditioners and heat pumps. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 6-1/2" x 9" x 3-1/4". UL869 service equipment, UL Listed.
GE Electrical TPF60R AC Disconnect Switches Cutler-Hammer ACD221RNMP AC Disconnect Switches
Single phase, 2 pole, 2 wire, 240 volt AC, non-metallic enclosure. Rated 1-1/2 HP at 120 volt, 3 HP at 240 volt with time delay fuses (uses class H cartridge fuses, not included). For top and bottom entry and exit, with provision for type H conduit hub. Heavy duty, high strength, rugged polymer enclosure with UV resistant features. 10,000 amp RMS symmetrical interrupting rating. Suitable for use as service entrance equipment with ground bar. No.GB4 ground bar and No.360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5" x 8.63" x 3.5". UL Listed file No. E5239.
   
 